Battery Model RN-60V-40Ah
Total Energy 2400Wh
Communication interface RS485
Nominal Capacity 40Ah
Minimum Capacity 40Ah
Nominal Voltage 60V
Charging Voltage 67.2V
Charging Protection Voltage 67v
Discharging Cut-off Voltage 48V
Discharging Rrotection Voltage 45V
Charging Protection Voltage 68V
Over current protection 100A
Standard Charging Method 0.2C CC(constant current) charge to 4.2 V, then CV (constant voltage 4.2 V) charge till charge current decline to 0.02C
Standard Discharging Method 0.2C electric constant exile to 3.0v .
Standard Charging Current 10A
Maximum Charging Current 20A
Charing Cut-off Current 0.2C
Standard Dischaging Current 20A
Maximum Charging Curren 60A
Max.Continuous Charge Current 15A
Max.Continuous Discharge Current 40A
Operating Temperature(Charging/Discharging) -20~50℃/ -40~50℃
Battery Weight(Approx) 23Kg
Battery Cells We provide solutions or according to customer requirements
Requirements For Input And Output Ports Set this parameter based on the actual situation
Battery Dimension  
Length 375mm
Width 245mm
Thickness 153mm
Storage Temperature -10~50℃
Storage Environment Battery should be stored in a cool, dry and well-ventilated area, and should be far from the fire and the high temperature.